Lumbar disc herniation is due to lumbar disc degeneration, fibrous ring rupture, the clinical symptoms of nucleus pulposus prolapse or after nerve root compression or cauda equina is shown, is the leading cause of clinical common disease and pain, bring a lot of pain to the patient's life and work, and even the loss of labor ability. Transforaminal discectomy is the most safe and effective method for the treatment of lumbar disc herniation.
Foraminal mirror from the patient side or the rear side into the intervertebral foramen, operation in the security triangle, bone tissue throughout the process of endoscopic direct observation on nucleus pulposus, dural sac and nerve root, hyperplasia, the use of all kinds of catch forcepsunder nucleus pulposus tissue, or in endoscopic removal of bone, RF repair damaged fiber ring electrode. Transforaminal endoscopic surgery procedures can be summarized as positioning, channel establishment, removal of nucleus pulposus in three steps, which, according to the established channel in different ways, divided into two ways and trephine bone drill grinding on the facet tip channel establishment.

In view of the development of the technique of intervertebral foramen endoscope surgery, Xinhua surgical instruments Co., Ltd. has launched a special set of surgical instruments for intervertebral foramen endoscope:


Nucleus forceps
![1493696164702665.png 0SL]$PPG_]@XS~2QBGCLE5T.png](/upload/1/editor/1724207043936.jpg)
Curved grasping forceps

Bite and cut forceps (Lan Qian)

Rongeur

Bone drill

Endoscopic trephine

Trephine

Positioner (TOM pin)

The handle, the handle trephine bone drill

Trepan putter

Regulator and Kirschner wire
![1493697400937490.png _@U7]9Z2E6NTZPDB7I)W34N.png](/upload/1/editor/1724207044424.jpg)
Guide wire

Three stage expansion tube

Trephine expansion tube

Work sleeve

Nerve dissector

Nerve retractor

Bone knife
![1493703664102247.png ECVW4B7EYAG]`14S_731L@B.png](/upload/1/editor/1724207044771.jpg)
Puncture needle

Bone hammer
This set of instruments has the following characteristics:
1) the head of the nucleus pulposus, the cutting forceps and so on, adopt a fine addition molding technology to ensure the consistency of products and good shearing properties, and improve the corrosion resistance of the products;
2) bone drill forming technology to avoid the risk of fracture at the end of the head;
3) the bone drill uses a unique cutting edge design to remove the chip from the body;
4) advanced deep hole processing technology, bone drill hole roughness can reach the specular level, ensure smooth guide bone penetration, avoid deformation of jam;
5) products covered by trephine and bone drill two channel establishing method, to meet the different choice of surgical methods;
6) high performance price ratio is the best choice to replace imported intervertebral hole mirror instruments.